When it is interfered or contaminated, grid power quality can't reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.
Tekniske specifikationer
Projekt | Data | |
Antal målekanaler | Fire spændingskanaler, fire strømkanaler | |
Måleområde | Spænding | 0-900V |
Nuværende | Lille klemme: diameter 8mm, 5A/25A (standard) Mellem klemme: diameter 50 mm, 100A/500A (valgfrit) Stor klemme: diameter 12550 mm, 400A/2000A (valgfrit) | |
Fase vinkel | 0.000-359.999 degree | |
Frekvens | 42.5-69Hz | |
Måletrin | Spænding | 0.001V |
Nuværende | 0.0001A | |
Fase vinkel | 0.001 grad | |
Strøm | aktiv effekt {{0}},01W,reaktiv effekt 0,01Var | |
Frekvens | 0.0001Hz | |
Spændingsmålenøjagtighed | Mindre end eller lig med 0,1 procent | |
Strømmålingsnøjagtighed | Mindre end eller lig med 0,3 procent | |
Fasevinkelmålingsnøjagtighed | Mindre end eller lig med 0,1 grad | |
Power measurement accuracy | Mindre end eller lig med 0,5 procent | |
Frequency measurement accuracy | Mindre end eller lig med 0.01Hz | |
Harmoniske analysetider | 2-64 times | |
Harmonisk spændingsmåling fejl | Harmonic content>1 percent Nominal value: Less than or equal to 1 percent RD Harmonic content<1 percent Nominal value: Less than or equal to 0.05 percent FS | |
Harmonisk strømmålingsfejl | Harmonic content>3 percent Nominal value: Less than or equal to 1 percent RD Harmonic content<3 percent Nominal value: Less than or equal to 0.05 percent FS | |
Trefaset spændingsubalancefejl | Mindre end eller lig med 0,2 procent | |
Trefaset strømubalancefejl | Mindre end eller lig med 0,5 procent | |
Spændingsudsvings nøjagtighed | 5 procent | |
PST-måletid | 10 min | |
PLT-måletid | 2h | |
PST/PLT målefejl | Mindre end eller lig med 5 procent | |
Skærm | 1280800, Ægte farve LCD | |
Opladningseffekt | AC220V±15 percent Frekvens 45Hz-65Hz | |
Standby timing | Større end eller lig med 10 timer | |
Værtskraft | <4VA | |
Isolering | 1) The insulation resistance between the voltage, current input terminal and the housing Less than or equal to 100MΩ. 2) Tåler 1,5KV (gyldig værdi) med strømfrekvens på driftsstrømindgang og skallen, som varer et minut. | |